2 INFORM Explanation
FS100 2.1 I/O Instructions : PULSE
2-12
2. B Variable number / LB Variable number / B [Array
number] / LB [Array number] / Byte type constant
When OG# (output group number) or OGH# (output group number) in the
above table is selected, choose one of the tags from the following table.
3. T=Time
The following tag can be added or omitted.
(1) PULSE OT#(128)
The pulse signal is output for 0.30 seconds to general output sig-
nal No.128.
(2) SET B000 5
PULSE OT#(B000) T=1.000
The pulse signal is output for 1.0 seconds to general output signal
No.5.
No. Tag Explanation Note
4 B Variable number/
LB Variable number/
B [Array Number] /
LB [Array Number]
Specifies the number of the corresponding pulse output
signal when the contents of the specified byte type
variable is expressed in bits.
Bit:
0: OFF
1: ON
5 Byte type constant Specifies the number of the corresponding pulse output
signal when the specified byte type constant is
expressed in bits.
No. Tag Explanation Note
6 T=Time Specifies the time during which the pulse signal is
output.
The pulse signal is output during the specified time T.
Units: seconds
Variable I/LI/I[]/LI[] can
be used.
(Units: 0.001 seconds)
When the time is not
specified, the pulse
signal is output during
0.30 seconds.
Example
Pulse signal
0.3sec
Pulse signal
ON
OFF
1.0 sec