2 INFORM Explanation
FS100 2.3 Operating Instruction : SETE
2-131
2. (Element number)
Add the following tag.
3. Double-precision type constant/D Variable number/
LD Variable number/D [Array number]/LD [Array
number]
Choose one of the tags from the following table.
(1) SETE P000 (3) 2000
2000 is set in the Z axis data of P000.
No. Tag Explanation Note
4 (Element number) Specifies the element of the position type variable to be
set.
Element No.: 1 to 255
Variable B/LB can be
used.
No. Tag Explanation Note
5 Double-precision
type constant
Specifies the double-precision type data to be set. <Data 2>
6 D Variable number/
LD Variable number/
D [Array number]/
LD [Array number]
Specifies the number of the double-precision type
variable to be set.
<Data 2>
Example

Other manuals for YASKAWA FS100