2 INFORM Explanation
FS100 2.1 I/O Instructions : DOUT
2-2
1. OT# (Output number) /OG# (Output group number) /
OGH# (Output group number)
Choose one of the tags from the following table.
2. OT# (Output number) /OG# (Output group number) /
OGH# (Output group number)
When OT# (output number) is selected from the table in part 1 of this
Explanation, choose one of the tags from the following table.
Explanation
No Tag Explanation Note
1 OT#(Output number) Specifies the output number signal. No:1 to 1024
Variable B/I/D/LB/LI/LD
can be used.
2 OG#(Output group
number)
Specifies the output number group signal (1group 8
points).
No:1 to 128
Variable B/I/D/LB/LI/LD
can be used.
3 OGH#(Output group
number)
Specifies the output number group signal (1group 4
points).
No:1 to 256
Variable B/I/D/LB/LI/LD
can be used.
SUPPLE
-MENT
Output signal
Output signal OT#(xx) is 1 point, OGH#(xx) is 1 group 4 points, and OG#(xx) is 1 group 8
points.
OT#(1)OT#(3) OT#(2)OT#(5) OT#(4)OT#(7) OT#(6)OT#(8)
OGH#(1)OGH#(2)
OG#(1)
No Tag Explanation Note
4 B Variable number/
LB Variable number
/
B [Array number]/
LB [Array number]
The least significant bit of the specified byte type
variable specifies on/off of the output signal.
Least significant bit:
0: OFF
1: ON
5 ON/OFF Specifies on/off of the output signal.
6 INVERT Refers the current signal status to output OFF when the
status is ON, and output ON when the status is OFF.