EasyManua.ls Logo

YASKAWA GA800

YASKAWA GA800
644 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter Details
2
2.2 A: Initialization Parameters
YASKAWA TOEPYAIGA8002B GA800 Drive Programming 191
and motoring/regeneration on the machine side before you use the function. If there is a polarity error, shock can
increase.
Item Description
Sequence Circuit Configuration
Time chart: Increase Enter the analog signal as the torque compensation (torque bias) signal as specified by the load quantity before drive operation until drive
operation completes. The default setting is 10 V/100% torque.
Enter a positive polarity during a motoring load, and enter a negative polarity during a regenerative load.
Time chart: Decrease Enter the analog signal as the torque compensation (torque bias) signal as specified by the load quantity before drive operation until drive
operation completes. The default setting is 10 V/100% torque.
Enter a negative polarity during a motoring load, and enter a positive polarity during a regenerative load.

Table of Contents

Other manuals for YASKAWA GA800

Related product manuals