EasyManua.ls Logo

YASKAWA GA800

YASKAWA GA800
644 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter Details
2
2.2 A: Initialization Parameters
YASKAWA TOEPYAIGA8002B GA800 Drive Programming 193
A1-12: Bluetooth ID
No.
(Hex.)
Name Description
Default
(Range)
A1-12
(1564)
Bluetooth ID
Sets the password necessary to use Bluetooth to control the drive with a smartphone or tablet.
-
(0000 - 9999)
A2: User Parameters
You can register frequently used parameters and recently changed parameters here to access them quickly. You can
show the registered parameters in [User Custom Parameters] in the main menu.
A2-01 to A2-32: User Parameters 1 to 32
No.
(Hex.)
Name Description
Default
(Range)
A2-01 to A2-32
(0106 - 0125)
User Parameters 1 to 32
You can select a maximum of 32 parameters for the drive and set them to parameters A2-01 to A2-32.
The [User Parameters] section of the keypad main menu shows the set parameters. You can
immediately access these set parameters.
Parameters in General-
Purpose Setup Mode
(Determined by A1-06)
Note:
Settings for A2-01 to A2-32 change when the A1-06 [Application Preset] value changes.
You must set A1-01 = 1 [Access Level Selection = User Parameters] to access parameters A2-01 to A2-32.
When A1-07 = 1 or 2 [DriveWorksEZ Function Selection = DWEZ Enabled or Enabled/Disabled wDigital Input], the drive saves qx-xx
[DriveWorksEZ Parameters] to A2-01 to A2-32.
The drive saves these parameters to A2-01 to A2-32.
The drive saves a maximum of 32 parameters.
Note:
Set A1-01 = 2 [Advanced Level] or A1-01 = 3 [Expert Level] to register the necessary parameters.
The drive automatically saves changed parameters to A2-17 to A2-32.
Note:
Set A2-33 = 1 [User Parameter Auto Selection = Enabled].
A2-33: User Parameter Auto Selection
No.
(Hex.)
Name Description
Default
(Range)
A2-33
(0126)
User Parameter Auto
Selection
Sets the automatic save feature for changes to parameters A2-17 to A2-32 [User Parameters 17 to
32].
Determined by A1-06
(0, 1)
0 : Disabled: Manual Entry Required
Set User Parameters manually.
1 : Enabled: Auto Save Recent Parms
The drive automatically registers changed parameter A2-17 to A2-32. The drive automatically saves the most recently
changed parameter to A2-17, and saves a maximum of 16 parameters. After the drive registers 16 parameters, when
you save a new parameter, the drive will remove a parameter from the User Parameter list to make space for the new
parameter. The drive removes parameters with First In, First Out.
You can show the registered parameters in [User Custom Parameters] in the main menu.
Note:
In General-Purpose Setup Mode, the drive registers parameters starting with A2-27 because the drive registers parameters A2-26 and lower
by default.
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV

Table of Contents

Other manuals for YASKAWA GA800

Related product manuals