Parameter List
1
1.4 A: Initialization Parameters
YASKAWA TOEPYAIGA8002B GA800 Drive Programming 21
No.
(Hex.)
Name Description
Default
(Range)
Ref.
A1-07
(0128)
DriveWorksEZ Function
Selection
Sets the drive to operate with DriveWorksEZ.
0 : DWEZ Disabled
1 : DWEZ Enabled
2 : Enabled/Disabled wDigital Input
0
(0 - 2)
192
A1-11
(111D)
Expert
Firmware Update Lock
Protects the drive firmware. When you enable the protection, you cannot update the drive
firmware.
0 : Disabled
1 : Enabled
0
(0, 1)
192
A1-12
(1564)
Bluetooth ID
Sets the password necessary to use Bluetooth to control the drive with a smartphone or
tablet.
-
(0000 - 9999)
193
◆ A2: User Parameters
No.
(Hex.)
Name Description
Default
(Range)
Ref.
A2-01 to A2-32
(0106 - 0125)
User Parameters 1 to 32
You can select a maximum of 32 parameters for the drive and set them to parameters A2-
01 to A2-32. The [User Parameters] section of the keypad main menu shows the set
parameters. You can immediately access these set parameters.
Note:
Settings for A2-01 to A2-32 change when the A1-06 [Application Preset] value
changes.
Parameters in General-
Purpose Setup Mode
(Determined by A1-06)
193
A2-33
(0126)
User Parameter Auto
Selection
Sets the automatic save feature for changes to parameters A2-17 to A2-32 [User
Parameters 17 to 32].
0 : Disabled: Manual Entry Required
1 : Enabled: Auto Save Recent Parms
Determined by A1-06
(0, 1)
193