EasyManua.ls Logo

YASKAWA GA800

YASKAWA GA800
644 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter Details
2
2.6 E: Motor Parameters
YASKAWA TOEPYAIGA8002B GA800 Drive Programming 307
E3-05: Motor 2 Maximum Output Voltage
No.
(Hex.)
Name Description
Default
(Range)
E3-05
(031B)
Motor 2 Maximum Output
Voltage
Sets the maximum output voltage for the motor 2 V/f pattern.
Determined by E3-01
(200 V Class: 0.0 - 255.0 V,
400 V Class: 0.0 - 510.0 V)
E3-06: Motor 2 Base Frequency
No.
(Hex.)
Name Description
Default
(Range)
E3-06
(031C)
Motor 2 Base Frequency
Sets the base frequency for the motor 2 V/f pattern.
Determined by E3-01
(0.0 - E3-04)
E3-07: Motor 2 Mid Point A Frequency
No.
(Hex.)
Name Description
Default
(Range)
E3-07
(031D)
Motor 2 Mid Point A
Frequency
Sets a middle output frequency for the motor 2 V/f pattern.
Determined by E3-01
(0.0 - E3-04)
E3-08: Motor 2 Mid Point A Voltage
No.
(Hex.)
Name Description
Default
(Range)
E3-08
(031E)
Motor 2 Mid Point A Voltage
Sets a middle output voltage for the motor 2 V/f pattern.
Determined by E3-01
(200 V Class: 0.0 - 255.0 V,
400 V Class: 0.0 - 510.0 V)
E3-09: Motor 2 Minimum Output Frequency
No.
(Hex.)
Name Description
Default
(Range)
E3-09
(031F)
Motor 2 Minimum Output
Frequency
Sets the minimum output frequency for the motor 2 V/f pattern.
Determined by E3-01
(0.0 - E3-04)
E3-10: Motor 2 Minimum Output Voltage
No.
(Hex.)
Name Description
Default
(Range)
E3-10
(0320)
Motor 2 Minimum Output
Voltage
Sets the minimum output voltage for the motor 2 V/f pattern.
Determined by E3-01
(200 V Class: 0.0 - 255.0 V,
400 V Class: 0.0 - 510.0 V)
E3-11: Motor 2 Mid Point B Frequency
No.
(Hex.)
Name Description
Default
(Range)
E3-11
(0345)
Expert
Motor 2 Mid Point B
Frequency
Sets a middle output frequency for the motor 2 V/f pattern. Set this parameter to adjust the V/f
pattern for the constant output range. Usually it is not necessary to change this parameter.
0.0 Hz
(0.0 - E3-04)
Note:
Set this parameter to 0.0 to disable the function.
When you initialize the drive, this parameter is reset to the default value.
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV

Table of Contents

Other manuals for YASKAWA GA800

Related product manuals