Parameter Details
2
2.10 n: Special Adjustment
YASKAWA TOEPYAIGA8002B GA800 Drive Programming 505
If too much current flows during acceleration, decrease the setting value.
Note:
When A1-02 = 8 [Control Method Selection = EZOLV], this parameter will always be in effect for speed ranges less than n7-10 [Pull-in
Current Switching Speed].
n8-52: ACR P Gain
No.
(Hex.)
Name Description
Default
(Range)
n8-52
(053F)
Expert
ACR P Gain
Sets the proportional gain of the current regulator. Usually it is not necessary to change this setting.
10.0
(-100.0 - 100.0)
n8-54: Voltage Error Compensation Time
No.
(Hex.)
Name Description
Default
(Range)
n8-54
(056D)
Expert
Voltage Error Compensation
Time
Sets the time constant that the drive uses when adjusting for voltage errors.
1.00 s
(0.00 - 10.00 s)
Adjust this parameter in these conditions:
If oscillation occurs at the time of start up, increase the setting value.
If hunting occurs when operating at low speed, increase the setting value.
If fast changes in the load cause hunting, increase the setting value in 0.1-unit increments. If you cannot stop
hunting, set n8-51 [Pull-in Current @ Acceleration] to 0% and set n8-54 to 0.00 s, and disable compensation for
voltage errors.
n8-55: Motor to Load Inertia Ratio
No.
(Hex.)
Name Description
Default
(Range)
n8-55
(056E)
Motor to Load Inertia Ratio
Sets the ratio between motor inertia and machine inertia.
0
(0 - 3)
Adjust in the following situations.
If torque and speed response is unsatisfactory, gradually increase the setting from 0.
If the motor does not run smoothly, gradually increase the setting from 0.
If the motor stalls during run at constant speed, gradually increase the setting from 0.
If there is vibration or hunting, decrease the setting.
Note:
If the value is set too low, the drive will detect STPo [Motor Step-Out Detected].
If you use one motor or more than motor at low inertia and the value is too high, there can be vibration in the motor.
0 : Below 1:10
Use this setting in these conditions:
The ratio between the motor inertia and machine inertia is less than 1:10
There are large current ripples
1 : Between 1:10 and 1:30
Use this setting in these conditions:
The ratio between the motor inertia and machine inertia is approximately 1:10 to 1:30
Parameter n8-55 = 0 and the drive detects STPo because of an impact load or sudden acceleration/deceleration.
2 : Between 1:30 and 1:50
Use this setting in these conditions:
The ratio between the motor inertia and machine inertia is approximately 1:30 to 1:50
Parameter n8-55 = 1 and the drive detects STPo because of an impact load or sudden acceleration/deceleration.
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV