EasyManua.ls Logo

YASKAWA GA800

YASKAWA GA800
644 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter List
1
1.9 F: Options
YASKAWA TOEPYAIGA8002B GA800 Drive Programming 59
No.
(Hex.)
Name Description
Default
(Range)
Ref.
F7-12
(03F0)
Gateway Address 4
Sets the fourth octet of the gateway address of the connected network.
Note:
Set this parameter when F7-13 = 0 [Address Mode at Startup = Static].
1
(0 - 255)
352
F7-13
(03F1)
Address Mode at Startup
Sets the method to set option card IP addresses.
0 : Static
1 : BOOTP
2 : DHCP
Note:
The following setting values are available when using the PROFINET
communication option card (SI-EP3).
0: Static
2: DHCP
When F7-13 = 0, set parameters F7-01 to F7-12 [IP Address 1 to Gateway Address
4] to set the IP Address. Be sure to set a different IP address for each drive on the
network.
2
(0 - 2)
352
F7-14
(03F2)
Duplex Mode Selection
Sets the duplex mode setting method.
0 : Half/Half
1 : Auto/Auto
2 : Full/Full
3 : Half/Auto
4 : Half/Full
5 : Auto/Half
6 : Auto/Full
7 : Full/Half
8 : Full/Auto
1
(0 - 8)
352
F7-15
(03F3)
Communication Speed
Selection
Sets the communications speed.
10 : 10/10 Mbps
100 : 100/100 Mbps
101 : 10/100 Mbps
102 : 100/10 Mbps
10
(10, 100 - 102)
352
F7-16
(03F4)
Timeout Value
Sets the detection time for a communications timeout.
Note:
Set this parameter to 0.0 to disable the connection timeout function.
0.0 s
(0.0 - 30.0 s)
353
F7-17
(03F5)
EtherNet/IP Speed
Scaling Factor
Sets the scaling factor for the speed monitor in the EtherNet/IP Class ID 2AH Object.
0
(-15 - +15)
353
F7-18
(03F6)
EtherNet/IP Current Scale
Factor
Sets the scaling factor for the output current monitor in the EtherNet/IP Class ID 2AH
Object.
0
(-15 - +15)
353
F7-19
(03F7)
EtherNet/IP Torque Scale
Factor
Sets the scaling factor for the torque monitor in the EtherNet/IP Class ID 2AH Object.
0
(-15 - +15)
353
F7-20
(03F8)
EtherNet/IP Power
Scaling Factor
Sets the scaling factor for the power monitor in the EtherNet/IP Class ID 2AH Object.
0
(-15 - +15)
353
F7-21
(03F9)
EtherNet/IP Voltage Scale
Factor
Sets the scaling factor for the voltage monitor in the EtherNet/IP Class ID 2AH Object.
0
(-15 - +15)
353
F7-22
(03FA)
EtherNet/IP Time Scaling
Sets the scaling factor for the time monitor in the EtherNet/IP Class ID 2AH Object.
0
(-15 - +15)
353
F7-23 - F7-27
(03FB - 03FF)
F7-28- F7-32
(0370 - 0374)
Dynamic Out Param 1 to
10 for CommCard
Sets Output Assembly 116. The drive writes the values from Output Assembly 116 to the
MEMOBUS/Modbus address register that is stored for each parameter. The drive will not
write the values from Output Assembly 116 to the registers when the MEMOBUS/Modbus
address is 0.
0 354
F7-33 - F7-42
(0375 - 037E)
Dynamic In Param 1 to
10 for CommCard
Sets Input Assembly 166. The drive sends the values from the MEMOBUS/Modbus
address registers stored for each parameter to Input Assembly 166. The drive returns the
default register value for the option card when the MEMOBUS/Modbus address is 0 and
the value sent to Input Assembly 166 is not defined.
0 354
F7-60
(0780)
PZD1 Write (Control
Word)
Sets the MEMOBUS/Modbus address for PZD1 (PPO output). PZD1 (PPO output)
functions as the STW when F7-60 = 0, 1, or 2.
0 354
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV