3.2
SVA-01 Module Setup
3-33
The following table shows the functions given above.
NoteYes: Operation possible, NO: Operation not possible.
[ c ] Motion Parameter Settings
Fixed Parameters Tab Page
Set the parameters required for motion control on the Fixed Parameters Tab Page.
For details on each of the fixed parameter settings, refer to 4.4.1 Motion Fixed Parameter Details.
Motion Fixed
Parameters
Motion Setting
Parameters
Motion
Monitoring
Parameters
Remarks
Axis Data Copy /Axis
Data Paste
Yes Yes No
Details Yes Yes Ye s
Parameters in bit
format only
Default Set Yes Yes N o
Setting Details
Axis Number
Select the desired axis number. Set the fixed parameters for each axis.
Servo Type
(Motor Type)
Displays the motor type.
No.
Displays the parameter number of the motion fixed parameter.
Name (Parameter Name)
Displays the parameter name.
Input Data (Set Data)
Input (or select) the parameter value.
Unit
Displays the units of the corresponding parameter.