6.1
SVB-01 Module Control Block Diagrams
6-21
[ b ] Setting Parameters
No. Name Setting Unit Default Value Setting Range
OW

00
RUN Commands
0000h Bit setting
OW

01
Mode 1
0000h Bit setting
OW

02
Mode 2
0000h Bit setting
OW

03
Function 1
0011h Bit setting
OW

04
Function 2
0033h Bit setting
OW

05
Function 3
0000h Bit setting
OW

08
Motion Command
0 0 to 26
OW

09
Motion Command Options
0000h Bit setting
OW

0A
Motion Subcommand
0 0 to 65535
OL

0C
Torque Reference
Depends on torque unit. 0
2
31
to 2
31
1
OW

0E
Speed Limit at Torque Reference
0.01% 15000
32768 to 32767
OL

10
Speed Reference
Depends on speed unit. 3000
2
31
to 2
31
1
OL

14
Positive Side Limiting Torque Setting at the Speed
Reference
Depends on torque unit. 30000
2
31
to 2
31
1
OL

16
Secondary Speed Compensation
Depends on speed unit. 0
2
31
to 2
31
1
OW

18
Speed Override
0.01% 10000 0 to 32767
OL

1C
Position Reference Setting
Reference unit 0
2
31
to 2
31
1
OL

1E
Positioning Completed Width
Reference unit 100 0 to 65535
OL

20
Positioning Completed Width 2
Reference unit 0 0 to 65535
OL

22
Deviation Abnormal Detection Value
Reference unit
2
31
1 0 to 2
31
1
OW

26
Position Complete Timeout
ms 0 0 to 65535
OL

28
Phase Compensation
Reference unit 0
2
31
to 2
31
1
OL

2A
Latch Zone Lower Limit
Reference unit
2
31
2
31
to 2
31
1
OL

2C
Latch Zone Upper Limit
Reference unit
2
31
1
2
31
to 2
31
1
OW

2E
Position Loop Gain
0.1/s 300 0 to 32767
OW

2F
Speed Loop Gain
Hz 40 1 to 2000
OW

30
Speed Feed Forward Compensation
0.01% 0 0 to 32767
OW

31
Speed Amends
0.01% 0
32768 to 32767
OW

32
Position Integration Time Constant
ms 0 0 to 32767
WWW.NNC.IR