9.4
Parameters That Are Automatically Updated
9-21
9.4.4 Parameters Updated at Self-configuration (SERVOPACK to MP2200/MP2300)
9.4.5 Parameters Updated at Self-configuration (MP2200/MP2300 to SERVOPACK)
The following parameters are updated automatically for any communication method and regardless
of the setting of bit A of fixed parameter 1.
* 1. Use T-REF as external torque limit input.
* 2. Use V-REF as external speed limit input.
MP2200/MP2300
SERVOPACK
SGD-N,
SGDB-N
NS100 NS115 SGDS
Setting
Parameters
Position Loop Gain
OW

2E
Cn-001A Pn102
Speed Loop Gain
OW

2F
Cn-0004 Pn100
Speed Feed Forward
Compensation
OW

30
Cn-001D Pn109
Position Loop Integration
Time Constant
OW

32
Pn11F
Speed Loop Integration
Time Constant
OW

34
Cn-0005 Pn101
S-curve Acceleration Time
OW

3A
Cn-0026 Pn812
MP2200/MP2300
SERVOPACK
SGD-N,
SGDB-N
NS100 NS115 SGDS
SERVO-
PACK
Parameters
P-OT Not valid.
Cn-0001
Bit 2
Pn50A.3
N-OT Not valid.
Cn-0001
Bit 3
Pn50B.0
Positive Software Limit via Servo Not valid.
Cn-0014
Bit 2
Pn801.0
Negative Software Limit via Servo Not valid.
Cn-0014
Bit 3
Electronic Gear Ratio B
(Numerator)
1
Cn-0024 Pn202 Pn20E
Electronic Gear Ratio A
(Denominator)
1
Cn-0025 Pn203 Pn210
Online Autotuning Not valid.
Pn110
DEC Signal Mapping Allocated.
Pn511.0
EXT1 Signal Mapping Allocated.
Pn511.1
EXT2 Signal Mapping Allocated.
Pn511.2
EXT3 Signal Mapping Allocated.
Pn511.3
Speed Control Option
1
Pn002.0
Torque Control Option
2
Pn002.1