Digital Operation Display Functions and Levels
4-7
4
* 1. The setting ranges for acceleration/deceleration times depends on the setting of C1-10 (Acceleration/deceleration Time Setting Unit). If C1-10 is set to
0, the setting range is 0.00 to 600.00 (s).
* 2. These are values for a 200 V class Inverter. Values for a 400 V class Inverter are double.
* 3. The factory setting will change when the control method is changed. (Close Loop Vector control factory settings are given.)
* 4. After autotuning, E1-13 will contain the same value as E1-05.
* 5. The factory setting depends on the Inverter capacity. (The value for a 200 V Class Inverter for 3.7 kW is given.)
* 6. The setting range is from 10% to 200% of the Inverter rated output current. (The value for a 200 V Class Inverter for 3.7 kW is given.)
F1-05
PG rotation 0: Phase A leads with forward run
command. (Phase B leads with
reverse run command.)
1: Phase B leads with forward run
command. (Phase A leads with
reverse run command.)
0 or 1 0 No No No Q 384H
PG Rotation
Sel
L1-01
Motor pro-
tection selec-
tion
Set to enable or disable the motor over-
load protection function using the elec-
tronic thermal relay.
0: Disabled
1: Protection for general purpose motor
(fan cooled)
2: Protection for frequency converter
motor (external cooled)
3: Protection for special vector control
motor
When the inverter power supply is turned
off, the thermal value is reset, so even if
this parameter is set to 1, protection may
not be effective.
When several motors are connected to
one Inverter, set to 0 and ensure that each
motor is equipped with a protection
device.
0 to 3 1 No Q Q Q 480H
MOL Select
Param-
eter
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO-
BUS
Regis-
te
r
V/f
Open
Loop
Vector
Closed
Loop
Vector
Display
http://nicontrols.com

Table of Contents

Related product manuals