4-6
E1-04
Max. output
frequency
(FMAX)
40.0 to
120.0
60.0 Hz No Q Q Q 303H
Max
Freqency
E1-05
Max. voltage
(VMAX)
0.0 to
255.0
*2
200.0 V
*2
No Q Q Q 304H
Max Voltage
E1-06
Base fre-
quency (FA)
0.0 to
120.0
60.0 Hz
*3
No Q Q Q 305H
Base Fre-
quency
E1-08
Mid. output
frequency
voltage (VB)
0.0 to
255
*2
11.0 V
*1 *2
No Q Q No 307H
Mid voltage
A
E1-09
Min. output
frequency
(FMIN)
0.0 to
120.0
0.5 Hz
*3
No
Q
Q A 308H
Min Fre-
quency
E1-10
Min. output
frequency
voltage
(VMIN)
0.0 to
255.0
*2
2.0 V
*1 *2
No Q Q No 309H
Min Voltage
E2-01
Motor rated
current
Sets the motor rated current in Amps.
This set value becomes the base value for
motor protection and torque limit. It is an
input data for autotuning.
1.75 to
35.00
*6
14.00 A
*5
No QQQ30EH
Mtr Rated
Power
E2-02
Motor rated
slip
Sets the motor rated slip.
This set value will become the reference
value for the slip compensation.
This parameter is automatically set dur-
ing autotuning.
0.00 to
20.00
2.73 Hz
*5
No QQQ30FH
Motor Rated
Slip
E2-03
Motor no-
load current
Sets the motor no-load current.
This parameter is automatically set dur-
ing autotuning.
0.00 to
13.99
*5
4.50 A
*5
No Q Q Q 310H
No-Load
Current
E2-04
Number of
motor poles
Sets the number of motor poles. It is an
input data for autotuning.
2 to 48 4 No No No Q 311H
Number of
Poles
E2-05
Motor line-
to-line resis-
tance
Sets the motor phase-to-phase resistance.
This parameter is automatically set dur-
ing autotuning.
0.000
to
65.000
0.771 Ω
*5
No Q Q Q 312H
Term Resis-
tance
E2-11
Motor rated
output power
Sets the rated output power of the motor.
This parameter is an input data for auto-
tuning.
0.00 to
650.00
3.70
*5
No Q Q Q 318H
Mtr Rated
Power
F1-01
PG constant
Sets the number of PG pulses per revolu-
tion
0 to
60000
1024 No No No Q 380H
PG Pulses/
Rev
Param-
eter
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO-
BUS
Regis-
te
r
V/f
Open
Loop
Vector
Closed
Loop
Vector
Display