Chapter1BasicConguration
ZXAN#write
EndofSteps
1.2.2ConfiguringtheOut-of-BandNM
Inout-of-bandNMmode,thenon-servicechannelisusedtotransmitthemanagement
informationsothatthemanagementchannelandservicechannelareseparated.
Comparedwiththein-bandNMmode,theout-of-bandNMmodeprovidesmorereliable
equipmentmanagementchannel.WhentheZXA10C300isfaulty,thenetworkequipment
informationcanbelocatedintimeandmonitoredinrealtime.
Prerequisite
YouhaveloggedintotheZXA10C300throughHyperT erminalandenteredadministrator
mode.
CongurationData
Table1-2liststhecongurationdataoftheout-of-bandNM.
Table1-2CongurationDataoftheOut-of-BandNM
ItemData
Out-of-bandNMIPaddress11.1.1.1/24
NexthopIPaddress11.1.1.254/24
NMserver(SNMPserver)IPaddress:10.2.1.1/24
Version:V2C
Communityname:public
Alarmlevel:notications
UDPport:162
Steps
1.Enterglobalcongurationmode.
ZXAN#configureterminal
Enterconfigurationcommands,oneperline.EndwithCTRL/Z.
ZXAN(config)#
2.Conguretheout-of-bandNMIPaddress.
ZXAN(config)#interfacemng1
ZXAN(config-if)#ipaddress11.1.1.1255.255.255.0
ZXAN(config-if)#exit
1-7
SJ-20130520164529-007|2013-06-30(R1.0)ZTEProprietaryandCondential