Switch Enabled–enable/disable the switch globally. When disabled, the switch cannot
be activated by any of the available codes (including user switch codes), by quick dial
button.
Switch mode–set the monostable/bistable mode for the switch. The switch is switched
off after a timeout in the monostable mode and switched on with the first activation and
off with the next activation in the bistable mode.
Switch-on durationset the switch-on time for a monostable switch. This value is not
applied in the bistable mode.
Controlled output–assign an electric output to the switch.Choose one of the available
intercom outputs: relay, power output, extender output. If you selectNone, the switch will
not control any electric output but can control external equipment via HTTP commands.
Output type–if you use the2N
®
IP Intercom - Security Relaymodule, set the output
type toSecurity. In theSecuritymode, the output works in the inverse mode, i.e. remains
closed and controls the2N
®
IP Intercom - Security Relaymodule using a specific pulse
sequence.If you use the inverse mode (i.e. the door is locked when voltage is applied), set
theinverseoutput type.In casemultiple switches are set to the same output but different
output types, the following priority will be applied: 1. security, 2. inverse, 3. normal.
Info
A switch activation value higher than 1 s can be set for the security output type. A
value equal to or higher than 0.1 s can be set for the normal and inverse output
types.