2N Access Unit Configuration Manual
70 / 134
Module Name–set the module name for input/output specification in the SetOutput,
GetInput and InputChanged objects in the2NAutomation.
Door–set the reader direction (Arrival, Departure) for the Attendance system purposes.
Associated Switch–set the switch to be activated after user authentication via this
module. If you set Door Lock Switch, the authentication rules specified in Hardware / Door
will be used.
Received Code Format– set the format for the codes to be received (Wiegand 26, 32, 37
and RAW).
Output Wiegand Group– assign the output Wiegand to a group to which the codes from
the connected card readers or Wiegand inputs can be resent.
Transmitted Code Format– set the format for the codes to be transmitted (26-bit, 32-bit,
37-bit and RAW format, 35-bit, Corp. 1000, 48-bit, Corp. 1000 and Auto).
Change Facility Code– set the first code part via Wiegand. This applies to Wiegand OUT
for 26-bit code format. Contact your security system supplier to know if the Facility Code is
requested.
Facility Code–define the2NIPdevice location in the security system. Enter a decimal
value for the location (0–255).