2N Access Unit Configuration Manual
•
•
•
If the function is enabled, all the switches get blocked for 30 minutes whenever the tamper is
activated. Blocking is active even after the device restart. Each port can be controlled
viaAutomation. Press theUNBLOCKbutton, disable the function or reset the configuration
factory values to unblock the switches.
Assigned input–select the logical input to which the tamper switch is to be
connected.TamperSwitchActivatedsignals the tamper switch activation.
Enable automatic switch blocking– block the switches by tamper activation for 30
minutes.
Switch blocking state–display and make switch blocking settings.
•
•
Note
From PCB version 599v2 up, each of the models is equipped with an optical tamper
switch.
From PCB version 599v2 up, the assigned input is indicated by a module pictogram
backlight. In lower PCB versions, it is indicated by the LED light on the right-hand
module side.
•
•
•
Note
Menu Digital Inputs is available for models:
2N
®
IP Verso
2N
®
IP Varioand 2N
®
IP Force if an internal card reader is installed
2NAccess Unit