2N Access Unit Configuration Manual
•
•
•
•
Operation Mode–set the authentication method for a mobile phone:
Tap in app– authentication has to be confirmed by tapping on an icon in the
application running in a mobile phone.
Touch mode– touch the card reader having a phone with paired2N
®
Mobile Keyto
confirm authentication.
I/O Module Configuration
Module Name– set the module name for input/output specification in theSetOutput,
GetInput and InputChanged objects inAutomation.
Wiegand Module Configuration
The Wiegand module is equipped with the input and outputWiegand interfaces, which are
mutually independent, have separate settings and can receive and send codes at the same time.
The Wiegand input helps you connect such equipment as RFID card readers, biometric readers
and so on. With the Wiegand output, you can connect the intercom to the security system in
your building, for example (to send IDs of the RFID cards tapped on the RFID reader or codes
received on any Wiegand input). The2N
®
Wiegand Isolatoris also equipped with one logical
input and one logical output, which can be controlled viaAutomation.
•
Warning
An upgrade to version 2.30 is followed by upgrades in the Bluetooth modules. A
downgrade to version 2.29 and lower may make the Bluetooth modules non-
functional.