116 Parameters
05.83 Motor current at fault Displays the motor current (01.07) at which fault occurred. -
0.00…30000.00 A Motor current at fault. See par.
46.05
05.84 Motor torque at fault Displays the motor torque (01.10) at which fault occurred -
-1600.0…1600.0% Motor torque at fault. See par.
46.03
05.85 Main status word at
fault
Displays the main status word (06.11) at which fault
occurred. For the bit list, see parameter 06.11 Main status
word.
0000h
0000h…FFFFh Main status word at fault. 1 = 1
05.86 DI delayed status at
fault
Displays the DI delayed status (10.02) at which fault
occurred. For the bit list, see parameter 10.02 DI delayed
status.
0000h
0000h…FFFFh DI delayed status at fault. 1 = 1
05.87 Inverter temperature
at fault
Displays the inverter temperature (05.11) at which fault
occurred.
-
-40…160°C Inverter temperature at fault. 1 = 1°C
05.88 Reference used at
fault
Displays the reference used (28.01/26.73/23.01) at which
fault occurred. The type of the reference depends on the
selected operation mode (19.01).
-
-500.00…500.00 Hz/
-1600.0…1600.0%/
30000.00…
30000.00 rpm
Reference used at fault. See par.
46.02/
See par.
46.03/
See par.
46.01
No. Name/Value Description Default
FbEq 16
Bit Name
0 Ready to switch ON
1 Ready run
2 Ready ref
3 Tripped
4 Not in use
5 Not in use
6 Not in use
7 Warning
8 Modulating
9 Remote
10 Net OK
11 User bit 0
12 User bit 1
13 User bit 2
14 Charging
15 User bit 3
ACS180 FW.book Page 116 Tuesday, March 9, 2021 2:25 PM