Fault tracing 333
Viewing warning/fault information
The drive is able to store a list of the active faults actually causing the drive to trip at
the present time. The drive also stores a list of faults and warnings that have
previously occurred.
For each stored fault, the panel shows the fault code, time and values of nine
parameters (actual signals and status words) stored at the time of the fault. The
values of the parameters for the latest fault are in parameters 05.8005.88.
For active faults and warnings, see
Main menu - Diagnostics - Active faults
Main menu - Diagnostics - Active warnings
Options menu - Active faults
Options menu - Active warnings
parameters in group 04 Warnings and faults (page 112).
For previously occurred faults and warnings, see
Main menu - Diagnostics - Fault & event log
Note: Active faults are also stored in the fault and event log.
parameters in group 04 Warnings and faults (page 112).
The event log can also be accessed (and reset) using the Drive composer PC tool.
See Drive composer PC tool user’s manual (3AUA0000094606 [English]).
QR Code generation for mobile service application
A QR Code (or a series of QR Codes) can be generated by the drive for display on
the assistant control panel. The QR Code contains drive identification data,
information on the latest events, and values of status and counter parameters. The
code can be read with a mobile device containing the ABB service application, which
then sends the data to ABB for analysis. For more information on the application,
contact your local ABB service representative.