122 Parameters
06.31 MSW bit 12 selection Selects a binary source whose status is transmitted as bit
12 (User bit 1) of 06.11 Main status word.
Ext run
enable
False 0. 0
True 1. 1
Ext run enable Status of the external run enable signal (see parameter
20.12 Run enable 1 source).
2
Other [bit] Source selection (see Terms and abbreviations). -
06.32 MSW bit 13 selection Selects a binary source whose status is transmitted as bit
13 (User bit 2) of 06.11 Main status word.
False
False 0. 0
True 1. 1
Other [bit] Source selection (see Terms and abbreviations). -
06.33 MSW bit 14 selection Selects a binary source whose status is transmitted as bit
14 (User bit 3) of 06.11 Main status word.
False
False 0. 0
True 1. 1
Other [bit] Source selection (see Terms and abbreviations). -
07
07 System info
Drive hardware and firmware information.
All parameters in this group are read-only.
07.03 Drive rating id Type of the drive/inverter unit. -
07.04 Firmware name Firmware identification. -
07.05 Firmware version Version number of the firmware. -
07.06 Loading package
name
Name of the firmware loading package. -
07.07 Loading package
version
Version number of the firmware loading package. -
07.11 Cpu usage Microprocessor load in percent. -
0…100% Microprocessor load. 1 = 1-
07.25 Customization
package name
First five ASCII letters of the name given to the
customization package. The full name is visible under
System info on the control panel or the Drive composer
PC tool.
_N/A_ = None.
-
07.26 Customization
package version
Customization package version number. Also visible
under System info on the control panel or the Drive
composer PC tool.
-
No. Name/Value Description Default
FbEq 16