Actual signals and parameters 167
Actual signals in the short parameter view
Parameters in the short parameter view
Actual signals in the short parameter view
No. Name/Value Description FbEq
04 FAULT HISTORY Fault history (read-only). See group 04 FAULT HISTORY in
the list of all parameters.
0401 LAST FAULT Code of the latest fault. 1 = 1
Parameters in the short parameter view
No. Name/Value Description Def/FbEq
11 REFERENCE
SELECT
Panel reference type, external control location selection and
external reference sources and limits. See group 11
REFERENCE SELECT in the list of all parameters.
1105 REF1 MAX Defines the maximum value for external reference REF1. E: 50.0 Hz
U: 60.0 Hz
12 CONSTANT
SPEEDS
Constant speed (drive output frequency) selection and
values. See group 12 CONSTANT SPEEDS in the list of all
parameters.
1202 CONST
SPEED 1
Defines constant drive output frequency 1. E: 5.0 Hz
U: 6.0 Hz
1203 CONST
SPEED 2
Defines constant drive output frequency 2. E: 10.0 Hz
U: 12.0 Hz
1204 CONST
SPEED 3
Defines constant drive output frequency 3. E: 15.0 Hz
U: 18.0 Hz
13 ANALOG INPUTS Analog input signal processing. See group 13 ANALOG
INPUTS in the list of all parameters.
1301 MINIMUM AI1 Defines the minimum %-value that corresponds to minimum
mA/(V) signal for analog input AI1.
1.0%
14 RELAY OUTPUTS Status information indicated through relay output, and relay
operating delays. See group 14 RELAY OUTPUTS in the list
of all parameters.
1401 RELAY
OUTPUT 1
Selects a drive status indicated through relay output RO 1. FAULT( -1)
16 SYSTEM
CONTROLS
Parameter view, Run enable, parameter lock etc. See group
16 SYSTEM CONTROLS in the list of all parameters.
1611 PARAMETER
VIEW
Selects the parameter view, ie which parameters are shown
on the control panel.
SHORT
VIEW
20 LIMITS Drive operation limits. See group 20 LIMITS in the list of all
parameters.
2008 MAXIMUM
FREQ
Defines the maximum limit for the drive output frequency. E: 50.0 Hz
U: 60.0 Hz
21 START/STOP Start and stop modes of the motor. See group 21
START/STOP in the list of all parameters.
2102 STOP
FUNCTION
Selects the motor stop function. COAST