128 Program features
Diagnostics
Transistor output
The drive has one programmable transistor output. The output can be used either as
a digital output or frequency output (0…16000 Hz). The update time for the
transistor/frequency output is 2 ms.
Settings
Diagnostics
Actual signals
Several actual signals are available:
Drive output frequency, current, voltage and power
Motor speed and torque
Intermediate circuit DC voltage
Active control location (LOCAL, EXT1 or EXT2)
Reference values
Drive temperature
Operating time counter (h), kWh counter
Digital I/O and analog I/O status
PID controller actual values.
Three signals can be shown simultaneously on the assistant control panel display
(one signal on the basic control panel display). It is also possible to read the values
through the serial communication link or through the analog outputs.
Settings
Actual signal Additional information
0161 Frequency input value
Parameter Additional information
Group 18 FREQ IN & TRAN OUT Transistor output settings
Actual signal Additional information
0163 Transistor output status
0164 Transistor output frequency
Parameter Additional information
1501 Selection of an actual signal to AO
1808 Selection of an actual signal to frequency output
Group 32 SUPERVISION Actual signal supervision