Fault tracing 319
5087 Parameter download from
source to destination drive
has failed because
parameter sets are
incompatible.
Check that source and destination drive
information are same. See parameters in group
33 INFORMATION.
5088 Operation has failed
because of drive memory
error.
Contact your local ABB representative.
5089 Download has failed
because of CRC error.
Contact your local ABB representative.
5090 Download has failed
because of data
processing error.
Contact your local ABB representative.
5091 Operation has failed
because of parameter
error.
Contact your local ABB representative.
5092 Parameter download from
source to destination drive
has failed because
parameter sets are
incompatible.
Check that source and destination drive
information are same. See parameters in group
33 INFORMATION.
ALARM CODE CAUSE WHAT TO DO