Parameters 255
45.14 Tariff selection Selects (or defines a source that selects) which pre-
defined energy tariff is used.
0 = 45.12 Energy tariff 1
1 = 45.13 Energy tariff 2
Energy tariff
1
Energy tariff 1 0. 0
Energy tariff 2 1. 1
DI1 Digital input DI1 (10.02 DI delayed status, bit 0). 2
DI2 Digital input DI2 (10.02 DI delayed status, bit 1). 3
DI3 Digital input DI3 (10.02 DI delayed status, bit 2). 4
DI4 Digital input DI4 (10.02 DI delayed status, bit 3). 5
Other [bit] Source selection (see Terms and abbreviations). -
45.17 Tariff currency unit Specifies the currency used for the savings calculations. EUR
Local currency The currency is determined by the language selection
(see parameter 96.01 Language).
100
EUR Euro. 101
USD US dollar. 102
45.18 CO2 conversion factor Defines a factor for conversion of saved energy into CO
2
emissions (kg/kWh or tn/MWh). For example,
45.10 Total saved CO2 = 45.02 Saved kW hours × 45.18
CO2 conversion factor (tn/MWh).
0.500
tn/MWh
0.000…65.535
tn/MWh
Factor for conversion of saved energy into CO
2
emissions.
1 = 1 tn/MWh
45.19 Comparison power Actual power that the motor absorbs when connected
direct-on-line and operating the application. The value is
used for reference when energy savings are calculated.
Note: The accuracy of the energy savings calculation is
directly dependent on the accuracy of this value. If nothing
is entered here, then the nominal motor power is used by
the calculation, but that may inflate the energy savings
reported as many motors do not absorb nameplate power.
0.00 kW
0.00…100000.00 kW Motor power. 1 = 1 kW
45.21 Energy calculations
reset
Resets the savings counter parameters 45.0145.10. Done
Done Reset not requested (normal operation), or reset
complete.
0
Reset Reset the savings counter parameters. The value reverts
automatically to Done.
1
No. Name/Value Description Default