EasyManua.ls Logo

ABB ACS380 Series - Page 327

ABB ACS380 Series
462 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Additional parameter data 327
32.10 Supervision 1 high Real -21474830.00…
21474830.00
-100 = 1
32.11 Supervision 1 hysteresis Real 0.00…100000.00 - 100 = 1
32.15 Supervision 2 function List 0…6 - 1 = 1
32.16 Supervision 2 action List 0…2 - 1 = 1
32.17 Supervision 2 signal Analog src --1 = 1
32.18 Supervision 2 filter time Real 0.000…30.000 s 1000 = 1 s
32.19 Supervision 2 low Real -21474830.00…
21474830.00
-100 = 1
32.20 Supervision 2 high Real -21474830.00…
21474830.00
-100 = 1
32.21 Supervision 2 hysteresis Real 0.00…100000.00 - 100 = 1
32.25 Supervision 3 function List 0…6 - 1 = 1
32.26 Supervision 3 action List 0…2 - 1 = 1
32.27 Supervision 3 signal Analog src --1 = 1
32.28 Supervision 3 filter time Real 0.000…30.000 s 1000 = 1 s
32.29 Supervision 3 low Real -21474830.00…
21474830.00
-100 = 1
32.30 Supervision 3 high Real -21474830.00…
21474830.00
-100 = 1
32.31 Supervision 3 hysteresis Real 0.00…100000.00 - 100 = 1
32.35 Supervision 4 function List 0…6 - 1 = 1
32.36 Supervision 4 action List 0…2 - 1 = 1
32.37 Supervision 4 signal Analog src --1 = 1
32.38 Supervision 4 filter time Real 0.000…30.000 s 1000 = 1 s
32.39 Supervision 4 low Real -21474830.00…
21474830.00
-100 = 1
32.40 Supervision 4 high Real -21474830.00…
21474830.00
-100 = 1
32.41 Supervision 4 hysteresis Real 0.00…100000.00 - 100 = 1
32.45 Supervision 5 function List 0…6 - 1 = 1
32.46 Supervision 5 action List 0…2 - 1 = 1
32.47 Supervision 5 signal Analog src --1 = 1
32.48 Supervision 5 filter time Real 0.000…30.000 s 1000 = 1 s
32.49 Supervision 5 low Real -21474830.00…
21474830.00
-100 = 1
32.50 Supervision 5 high
Real -21474830.00…
21474830.00
-100 = 1
32.51 Supervision 5 hysteresis Real 0.00…100000.00 - 100 = 1
32.55 Supervision 6 function List 0…6 - 1 = 1
32.56 Supervision 6 action List 0…2 - 1 = 1
32.57 Supervision 6 signal Analog src --1 = 1
32.58 Supervision 6 filter time Real 0.000…30.000 s 1000 = 1 s
No. Name Type Range Unit FbEq32

Table of Contents

Other manuals for ABB ACS380 Series