Additional parameter data 339
58.82 RPDO6 COB-ID Real 0...7FFh - 1 = 1
58.83 RPDO6 transmission type Real 0...255 - 1 = 1
58.84 RPDO6 event timer Real 0...65535 ms 1 = 1 ms
58.85 TPDO6 COB-ID Real 0...7FFh - 1 = 1
58.86 TPDO6 transmission type Real 0...255 - 1 = 1
58.87 TPDO6 event timer Real 0...65535 ms 1 = 1 ms
58.88 RPDO21 COB-ID Real 0...7FFh - 1 = 1
58.89 RPDO21 transmission type Real 0...255 - 1 = 1
58.90 RPDO21 event timer Real 0...65535 ms 1 = 1 ms
58.91 TPDO21 COB-ID Real 0...7FFh - 1 = 1
58.92 TPDO21 transmission type Real 0...255 - 1 = 1
58.93 TPDO21 event timer Real 0...65535 ms 1 = 1 ms
58.101 Data I/O 1 Analog src --1 = 1
TPDO1 word 1 Analog src --1 = 1
58.102 Data I/O 2 Analog src --1 = 1
TPDO1 word 2 Analog src --1 = 1
58.103 Data I/O 3 Analog src --1 = 1
TPDO1 word 3 Analog src --1 = 1
58.104 Data I/O 4 Analog src --1 = 1
TPDO1 word 4 Analog src --1 = 1
58.105 Data I/O 5 Analog src --1 = 1
RPDO1 word 1 Analog src --1 = 1
58.106 Data I/O 6 Analog src --1 = 1
RPDO1 word 2 Analog src --1 = 1
58.107 Data I/O 7 Analog src --1 = 1
RPDO1 word 3 Analog src --1 = 1
58.108 Data I/O 8 Analog src --1 = 1
RPDO1 word 4 Analog src --1 = 1
58.109 Data I/O 9 Analog src --1 = 1
TPDO6 word 1 Analog src --1 = 1
58.110 Data I/O 10 Analog src --1 = 1
TPDO6 word 2 Analog src --1 = 1
58.111 Data I/O 11 Analog src --1 = 1
TPDO6 word 3 Analog src
--1 = 1
58.112 Data I/O 12 Analog src --1 = 1
TPDO6 word 4 Analog src --1 = 1
58.113 Data I/O 13 Analog src --1 = 1
RPDO6 word 1 Analog src --1 = 1
58.114 Data I/O 14 Analog src --1 = 1
RPDO6 word 2 Analog src --1 = 1
58.115 RPDO6 word 3 Analog src --1 = 1
No. Name Type Range Unit FbEq32