364 Fault tracing
80B5 Signal supervision
(Editable message text)
Programmable fault:
32.56 Supervision 6 action
Fault generated by the signal
supervision 6 function.
Check the source of the fault (parameter
32.57 Supervision 6 signal).
9081 External fault 1
(Editable message text)
Programmable fault: 31.01
External event 1 source
31.02 External event 1
type
Fault in external device 1. Check the external device.
Check setting of parameter 31.01
External event 1 source.
9082 External fault 2
(Editable message text)
Programmable fault: 31.03
External event 2 source
31.04 External event 2
type
Fault in external device 2. Check the external device.
Check setting of parameter 31.03
External event 2 source.
9083 External fault 3
(Editable message text)
Programmable fault: 31.05
External event 3 source
31.06 External event 3
type
Fault in external device 3. Check the external device.
Check setting of parameter 31.05
External event 3 source.
9084 External fault 4
(Editable message text)
Programmable fault: 31.07
External event 4 source
31.08 External event 4
type
Fault in external device 5. Check the external device.
Check setting of parameter 31.07
External event 4 source.
9085 External fault 5
(Editable message text)
Programmable fault: 31.09
External event 5 source
31.10 External event 5
type
Fault in external device 5. Check the external device.
Check setting of parameter 31.09
External event 5 source.
FA81 Safe torque off 1 Safe torque off function is
active, ie. STO circuit 1 is
broken.
Check safety circuit connections. For
more information, see chapter The Safe
torque off function in the hardware
manual of the drive and description of
parameter 31.22 STO indication run/stop
(page 203).
Check the value of parameter 95.04
Control board supply.
FA82 Safe torque off 2 Safe torque off function is
active, ie. STO circuit 2 is
broken.
FF61 ID run Motor ID run was not
completed successfully.
Check the nominal motor values in
parameter group 99 Motor data.
Check that no external control system is
connected to the drive.
Cycle the power to the drive (and its
control unit, if powered separately).
Check that no operation limits prevent
the completion of the ID run. Restore
parameters to default settings and try
again.
Check that the motor shaft is not locked.
FF81 FB A force trip A fault trip command has been
received through fieldbus
adapter A.
Check the fault information provided by
the PLC.
Code
(hex)
Fault / Aux. code Cause What to do