184 Technical data
Maximum recommended motor
cable length
Operational functionality and motor cable length
The drive is designed to operate with optimum performance
with the following maximum motor cable lengths.
Note: Conducted and radiated emissions of these motor
cable lengths do not comply with EMC requirements.
Note: In multimotor systems, the calculated sum of all
motor cable lengths must not exceed the maximum motor
cable length given in the table.
Frame
size
Maximum motor cable length, 4 kHz
Scalar control Vector control
m ft m ft
Standard drive, without external options
R1 100 330 100 330
R2 200 660 200 660
R3 300 990 300 990
R4 300 990 300 990
R5 300 990 300 990
R6 300 990 300 990
R7 300 990 300 990
R8 300 990 300 990
R9 300 990 300 990
3AXD00000586715.xls J