2 Installation and commissioning
2.6.5. Securing the base plate
773HAC026876-001 Revision: F
© Copyright 2007-2010 ABB. All rights reserved.
Recommendations, quality
The table specifies any recommendations made by ABB:
Base plate
This section details how to secure the base plate to the foundation.
Variable Recommendation
Recommended foundation quality 1 Steel fibre reinforced concrete foundation, 30 kg/m3,
class K30, t=250 mm
Recommended foundation quality 2 Sturdy concrete foundation, double reinforced by ø10
mm steel bars, distance 140 mm, class K25, t=250
Recommended bolt quality and
dimension
Hilti HDA-P, M20 x 250/50 (maximum thickness of
base plate = 50 mm)
Hilti HDA-P, M20 x 250/100 (maximum thickness of
base plate = 100 mm)
Action Note
1. Make sure the foundation is level.
2.
CAUTION!
The base plate weighs 353 kg! All lifting
equipment used must be sized accordingly!
3. Orient the base plate in relation to the robot
work location using the three grooves in the
base plate.
Shown in the figure Base plate, grooves
and holes on page 76.
4. Lift the base plate to its mounting position. Detailed in section Lifting the base plate
on page 73.
5. Use the base plate as a template and drill 16
attachment holes as required by the selected
bolt dimension.
If possible, observe the recommenda-
tions specified in section Recommenda-
tions, quality on page 77. ABB does not
assume any responsibility for other
foundation qualities, due to great
variations in the foundation properties.
6. Fit the base plate and use the levelling bolts to
level the base plate.
Shown in the figure Base plate, grooves
and holes on page 76.
7. If required, fit strips of sheet metal underneath
the base plate to fill any gaps.
8. Secure the base plate to the foundation with
screws and sleeves.
9. Recheck the four robot contact surfaces on
the base plate to make sure they are level and
flat.
If they are not, pieces of sheet metal or similar
may be used to bring the base plate to a level
position.
Maximum allowed deviation: 0.5 mm