Unpacking and handling
Moving the carriage manually
3HEA 800 970-001 Rev. D, Mars 2006 2-3
Installation and operation
1.3 Moving the carriage manually
1.3.1 Release the brake from the BRB
The carriage can be moved manually if necessary by connecting the power and
releasing the brake.
Release the brake when connecting the motor
If there is no power to the motor, 24 VDC can be connected to the motor’s power
cable.
Low voltage
motors
The following instructions apply to low voltage motors.
High voltage
motor
The following instructions apply to high voltage motors.
Action
1. Press the brake release button.
Action
1. Connect 24 VDC to pins M and L on connector MP.M7 (power cable, 3HXD 1249).
2. Press the brake release button.
Action
1. Connect 24 VDC to pins V and W on connector MP.M7/M8.
2. Press the brake release button.
Power cable Art. no.
BRB 3HEA 800 803
SMB, carriage 3HEA 800 827
SMB, floor 3HEA 800 813