Maintenance instructions
Filling the central lubrication system
3-6 3HEA 800 970-001 Rev. D, Mars 2006
Maintenance
2.1.9 Filling the central lubrication system
If the central lubrication system is empty, new lubricant is added as follows:
• The tank holds 2.71 kg (6 Lb Cyl)
Use ball element grease as specified in NLGI 1, for example:
Action Info/Illustration
1. Connect the supplied filling nipple at
position 1.
2. Fill with lubricant as specified below.
Manufacturer Lubricant
Q8 Q8 Rembrandt EP1
Mobil Mobilux EP1