Mechanical installation
Adjusting the level
2-10 3HEA 800 970-001 Rev. D, Mars 2006
Installation and operation
2.3.3 Adjusting the level
It is recommended that a laser level be used in the track motion's direction of travel
and a spirit level across this to obtain satisfactory adjustment. Always measure on a
machined surface, for example, for the linear guide or gear rack.
Follow the instructions below to adjust the level of the beam units.
The distance between the leveling bolts and the top edge of the ground plates must be at least
10 mm.
Action Info/Illustration
1. Turn the leveling bolts to raise or lower the
ground plates.
The distance between the leveling bolts
and the top edge of the ground plates must
be at least 10 mm.
2. Repeat all round until the module is
aligned within the given tolerance.
Min 10 mm