EasyManua.ls Logo

ABB PickMaster Twin - PowerPac - Page 127

ABB PickMaster Twin - PowerPac
454 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Trigger/Filter Setting
xx1800001444
Description
Select Trigger type to define when to generate new item posi-
tions.
Trigger Setting
If the trigger type is set to Distance the trigger distance must
be defined in the Trigger distance box.
A distance trigger can only be used with a conveyor work area
and the entered value is the distance the conveyor should move
between consecutive triggers.
If the trigger type is set to I/O, the trigger distance are pre-
defined.
CAUTION
If the Predefined and IO sensor are selected in the recipe, tune
the pick location in the Tuning for a radial distance to make up
the offset.
Continues on next page
Application manual - PickMaster® Twin - PowerPac 127
3HAC064218-001 Revision: B
© Copyright 2021 ABB. All rights reserved.
4 Working with PickMaster PowerPac
4.2.9 Adding Recipe
Continued

Table of Contents

Related product manuals