Vision error codes
DescriptionTypeError code
There is no frame grabber/Gigabit Ethernet camera installedStatus12298
Could not find the camera in question in the vision server.Internal Er-
ror
12299
Could not find the vision model in question in the vision
server.
Internal Er-
ror
12300
The camera is locked.Internal Er-
ror
12301
Attempt to create or load a camera that already exists.Internal Er-
ror
12302
The current frame grabber does not support the selected
video format.
Error12305
Failed to create camera.Internal Er-
ror
12306
The vision server could not find the acquired camera during
runtime.
Internal Er-
ror
12307
A camera is triggered too fast.Warning12308
Reason: A camera was triggered before it was done analyzing
the last image. As long as there only are a few messages
there will be no lost images.
Solution: Adjust the vision models on the camera to yield a
faster analyzing time. Adjust models on other cameras since
it is the system performance in total that should be improved.
Lowering the conveyor speed will also reduce the problem,
if applicable.
Failed to get an image from a camera when running a project.Error12309
Reason: This error probably occurred because the system is
too heavily loaded or the frame grabber is triggered way too
fast.
Solution: Verify system load and make sure the robot control-
ler does not send faulty vision triggers.
Failed to create a geometric model.Internal Er-
ror
12310
Reason: See error message for more information.
Attempt to access a camera port on a frame grabber that does
not exist.
Internal Er-
ror
12312
There is no camera port on the frame grabber specified for
the camera.
Internal Er-
ror
12313
Solution: Open the corresponding line and configure the
camera with a camera port.
Could not initiate the camera at project start.Error12315
Reason: The system is probably out of resources.
External model failed to analyze image.Error12316
Reason: See log message for more information
Failed to initiate external model at project start.Error12317
Reason: See log message for more information
Failed to convert image to a format supported by external
vision model.
Error12318