DescriptionTypeError code
External model failed to inspect image.Error12319
Reason: See log message for more information
When the line was opened, more than one camera was
defined to use the same port on the same frame grabber.
Only one camera can be configured to use a single camera
port and hence the other cameras were reset and must be
configured again.
Error12321
When the line was opened, a camera was defined on a frame
grabber that was not available. The camera was reset and
must be configured again.
Error12322
Could not initiate the camera. More information is provided
in the log message.
Error12323
Failed to save camera configuration. More information is
provided in the log message
Error12324
Failed to load camera configuration. More information is
provided in the log message.
Error12325
Failed to load vision model configuration. More information
is provided in the log message
Error12326
Failed to communicate with Gigabit Ethernet camera.Warning12329
Reason: Bad Ethernet connection or excessive Ethernet
communication.
Images are triggered too frequently.Warning12330
Solution: Adjust vision models to be less time consuming, or
decrease trigger frequency.
Connection to camera is lost, attempting to reconnect.Warning12331
Reason: Ethernet cable or power cable has been disconnec-
ted.
Image Buffer Full. More information is provided in the log
message.
Warning12332
A Gigabit Ethernet camera was found, but no such license
was detected.
Warning12333
Reason: No USB stick with vision license is inserted in the
PC.
A license for Gigabit Ethernet vision was detected, but no
such camera was found.
Warning12334
Reason: Camera is not connected, not turned on, or has an
invalid IP-address.
Failed to read parameter from camera.Warning12337
Reason: Check if the appropriate Cognex Drivers are installed.
If the problem persits, check network connections.
Cognex USB License dongle is attached.Status12341
Cognex USB License dongle is removed.Warning12342
Application manual - PickMaster® Twin - PowerPac 443
3HAC064218-001 Revision: B
© Copyright 2021 ABB. All rights reserved.
7 Troubleshooting
7.5 Error codes
Continued

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB PickMaster Twin - PowerPac and is the answer not in the manual?

ABB PickMaster Twin - PowerPac Specifications

General IconGeneral
BrandABB
ModelPickMaster Twin - PowerPac
CategoryRobotics
LanguageEnglish

Related product manuals