EasyManua.ls Logo

Adixen ASM GRAPH D+ - Configuration Ticket

Default Icon
336 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
B
320
Connecting the detector directly to
a
p
r
i
n
t
e
r
or
another
de
v
i
c
e
GB
00216
- Edition 02 - September
04
Configuration ticket
1
ASM1002
C
O
N
F
I
G
U
R
A
T
I
O
N
T
I
C
K
E
T
VE
R
S
I
O
N
:
L
125
v
1.0
r
00
DA
T
E
:
J
a
n
/
01
/
2003
T
I
M
E
:
00
:
00
:
07
S
E
T
-
P
O
I
N
T
S MENUS
audio
l
e
v
e
l
:
3
d
i
g
i
t
a
l
voice
l
e
v
e
l
:
3
hard vacuum
a
l
a
r
m
:
f
i
x
ed
hard vacuum
reject point:
1.0
E
-
07
s
n
i
ff
i
n
g
a
l
a
r
m
:
f
i
x
ed
s
n
i
ff
i
n
g
reject point:
1.0
E
-
04
sniffer
probe
c
l
o
gged
reject:
1.0
E
-
06
bargraph
zoom on reject point:
n
o
dep
o
ll
u
t
i
o
n
f
u
nc
t
i
o
n
:
o
ff
p
o
ll
u
t
i
o
n
reject point:
1.0
E
-
05
a
n
t
i
p
o
ll
u
t
i
o
n
G
L
f
u
nc
t
i
o
n
:
o
n
p
o
ll
u
t
i
o
n
reject point:
3.0
E
-
04
memo.
f
u
nc
t
i
o
n
a
c
t
i
v
e
:
n
o
memo.
d
i
s
p
l
a
y
timer:
n
o
memo. timer
v
a
l
u
e
(
m
i
n
:
s
)
:
00
:
10
c
y
c
l
e
end
f
u
nc
t
i
o
n
:
o
pe
r
a
t
o
r
roughing
o
v
e
r
l
a
p
timer:
o
n
roughing timer
v
a
l
u
e
(
m
i
n
:
s
)
:
00
:
10
test timer
v
a
l
u
e
(
m
i
n
:
s
)
:
00
:
10
s
t
a
r
t
.
t
i
m
e
r
v
a
l
u
e
(
m
i
n
:
s
)
:
00
:
05
background
su
pp
r
e
ss
i
o
n
a
c
t
i
v
a
t
i
o
n
:
o
pe
r
a
t
o
r
trigger: reject
p
o
i
n
t
G
L
setpoint
(
m
b
a
r
)
1.0
E
+
02
N
o
r
m
a
l
setpoint
(
m
b
a
r
)
1.0
E
-
01
S
P
E
C
T
R
O
MENUS
a
u
t
o
m
a
t
i
c
c
a
l
i
b
r
a
t
i
o
n
:
o
ff
c
a
l
i
b
r
a
t
i
o
n
check:
o
pe
r
a
t
o
r
every:
0050
c
y
c
l
e
s
every:
0010
h
o
urs
f
i
l
a
m
e
n
t
in use:
2
e
l
e
c
t
r
o
n
i
c
zero:
110
a
cc
e
l
e
r
a
t
i
o
n
v
o
l
t
a
ge
(V)
:
217
e
l
e
c
t
r
o
n
i
c
current(mA):
0.0
sensitivity
c
o
e
ff
i
c
i
e
n
t
:
01.00
He
c
a
l
i
b
r
a
t
ed
l
e
a
k
l
o
c
a
t
i
o
n
:
i
n
t
e
r
n
a
l
v
a
l
u
e
:
1.0
E
-
07
unit:
m
b
a
r
.
l
/
s
e
c
year:
2003
l
o
ss per
y
e
a
r
(
%
)
:
2.00
t
e
m
pe
r
a
t
ur
e
(
C
)
:
20
t
e
m
p
.
c
o
e
ff
i
c
i
e
n
t(
%
/
C
)
:
3.00
M
A
I
N
T
E
N
A
N
C
E
MENUS
high
v
a
c
.
m
n
t
.
pe
r
i
o
d
i
c
i
t
y
(
h
o
urs
)
:
12000
high
v
a
c
.
mnt.due in(hours):
12000
f
i
l
a
m
e
n
t
#1
running time(hours):
0
f
i
l
a
m
e
n
t
#2
running time(hours):
0
customed
m
n
t
.
pe
r
i
o
d
.
(
c
y
c
l
e
s
)
:
5.0
E
+
05
customed mnt.due
i
n
(
c
y
c
l
e
s
)
:
5.0
E
+
05
b
i
c
o
l
o
r
e
remote:
y
e
s
primary
pump1 used:
y
e
s
primary
pump2 used:
n
o
O
T
H
E
R
MENUS
test mode s
e
l
e
c
t
i
o
n
:
n
o
r
m
a
l
i
n
l
e
t
vent mode:
ch
a
m
be
r
i
n
l
e
t
vent
de
l
a
y
(
s
e
c
)
:
0
i
n
l
e
t
vent open timer us:
n
o
i
n
l
e
t
vent timer
v
a
l
u
e
(
m
i
n
/
s
e
c
)
:
00
:
09
hard vacuum
correction:
o
ff
hard vacuum
c
o
r
.
c
o
e
ff
i
c
i
e
n
t
:
1.00
E
+
00
s
n
i
ff
i
n
g
correction:
o
ff
s
n
i
ff
i
n
g
c
o
r
.
c
o
e
ff
i
c
i
e
n
t
:
1.00
E
+
00
unit:
m
b
a
r
.
l
/
s
e
c
d
i
s
p
l
a
y
l
a
n
g
u
a
ge
:
e
n
g
l
i
s
h
user
i
n
t
e
r
f
a
c
e
:
#4
password
v
a
l
u
e
:
5555
T
Y
P
I
C
A
L
VACUUM
V
A
L
U
E
S
P
u_
g
f
:
1.00000
Mu_
g
f
:
1.0
E
+
06
Pu_n
:1.00000
Mu_n
:
00001.0
Mu_r
l
d
:
00015.0
DATE
AND
T
I
M
E
V
A
L
U
E
S
l
a
s
t
stop:
J
a
n
/
01
/
2003
00
:
00
:
00
l
a
s
t
s
t
a
r
t
:
J
a
n
/
01
/
2003
00
:
00
:
02
l
a
s
t
c
a
l
i
b
.
o
k
:
J
a
n
/
01
/
2003
00
:
00
:
00
detector counter (h:m:s):
00000
:
00
:
50
3
/5

Table of Contents

Related product manuals