BZ001M056A ADT‐DK300A/400A Engraving Machine
95
Authority : Operationadminorhigher
Default : 0
Effectivetime : Instant
Note : Control mode corresponding to principal axis S code (frequency
conversionmode)
0:Analogoutput
1:Sectionspeedregulation(4‐digitcode),asbelow:
OUT23‐‐‐‐‐‐S0
OUT22‐‐‐‐‐‐S1
OUT21‐‐‐‐‐‐S2
OUT20‐‐‐‐‐‐S3
Inanalogoutputmode,theanalogvoltageis:
V=S/MaxRPM
Sistherotationsetbytheuser,andMaxRPMisthemaximumrotation
ofprincipalaxissetbytheparameter(P4.017);
Inswitchingquantitymode,constituteblock0‐15accordingtofour‐digit
codetooutput;Scodevalueisrestrictedto0‐
15;
062
XZeroReturnSpeed
063
YZeroReturnSpeed
064
ZZeroReturnSpeed
065
4ZeroReturnSpeed
Range : 0~9999
Unit : mm/min
Authority : Operationadminorhigher
Default : 1000
Effectivetime : Instant
Note : Set the home speed of every axis separately; both program home and
mechanicalhomeusethisparameter
066 SafeSignalELevel
Range : 0~1
Unit : LOGICVOLTAGELEVEL
Authority : Operationadminorhigher
Default : 0
Effectivetime : Instant
Note :
Settheeffectivevoltagelevelofthesystemsafetysignal.Thesourceof
safety signal can be customized by the user, and generally may be