BZ001M056A ADT‐DK300A/400A Engraving Machine
96
electriccabinetdoorandsimilarsensitiveoccasions.Ifthereareseveral
insecure places, please connect the signals in parallel to safety signal
testpinofthesystem.
Consideringtheconvenienceofmaintenance,safetysignalsarechecked
onlywhenthesystemstartsprocessing,andwon’tpromptinidlestate.
067
PressureSignalELevel
068
ChuckSignalELevel
Range : 0~1
Unit : LOGICVOLTAGELEVEL
Authority : Operationadminorhigher
Default : 0
Effectivetime : Instant
Note :
Set the effective voltage level of system air pressure alarm; set the
eff ectivevoltagelevelofsystemchuckalarm.
Both air pressure alarm and emergency stop alarm are
eff ective
globally;thedetectionportsofairpressurealarmandchuckalarmare
setinportparameters.
069
OilPressureOpen(min)
070
OilPressureKeep(sec)
071
OilPressureOutFreq(Hz)
072 OilInspectELevel
Range : 0~100001~100000~1000,~1
Unit : MinSecHzLOGICVOLTAGELEVEL
Authority : Operationadminorhigher
Default : 0,1,0,0
Effectivetime : Instant
Note :
Setthesystemlubricatingfunction.
Oil pressure timing open parameter controls the lubrication timing
function, 0 is to turn off the lubrication,
non‐zero is to turn on the
lubricationportafterthetimespecifiedbytimingparameters(min);the
oil pressure hold time sets the hold time of output lubrication port
(unit: second),oil control frequency is to controlthelubricationsignal
output mode, 0 is the jog mode, non ‐zero is
the time to control the