BZ001M056A ADTDK300A/400A Engraving Machine
97
lubrication signal in the output holding time (unit: HZ). Oil pressure
detectionlevelparameteristosetwhetherdetecttheeff ectivelevelin
the holding time. Lubrication output port and oil pressure detection
portaresetbyparameters066and078.
073
SpindleAlarmELevel
074
TransduserAlarmELevel
Range : 0~1
Unit : LOGICVOLT AGELEVEL
Authority : Operationadminorhigher
Default : 0
Effectivetime : Instant
Note : Theabovealarms arecheckedwhilethesystemisrunning. Thesystem
alarmsoncethetestisvalid.
ThisportisaffectedbyIOconfiguration.
075
ExScramELevel
082
ExStartELevel
083
ExPauseELevel
Range : 0~1
Unit : LOGICVOLTAGELEVEL
Authority : Operationadminorhigher
Default : 0
Effectivetime : Instant
Note :
Externalemergencystop,startandpausebuttonofthesystem
Theeffectivelevelforextendedfunctiondetection;thisportisaffected
byIOconfiguration.
076 BackHomeModeConf(bit)
Range : 0~10000
Unit : None
Authority : Operationadminorhigher
Default : ZXY
Effectivetime : Instant
Note :
Configuretheaxisandorderofautomaticbackhome ofthesystem.
Be default, it backs to Zaxis first and then XY axis. Other home mode