BZ001M056A ADTDK300A/400A Engraving Machine
99
acceleration/deceleration, and this parameter is valid in preprocessing
mode.
084
HOMECheckforalarm
085
HOMECheckEnable
Range : 0~1
Unit : None
Authority : Operationadminorhigher
Default : 0,1
Effectivetime : Instant
Note : Used to set whether prompt user to reset under certain conditions,
ensuringthattheuserhasperformedtheoperation;
Ifthevalueissetto0,itwon’tcheck,andwillrundirectly.
087 Defaultprocessplane
Range : G17,18,19
Unit : None
Authority : Operationadminorhigher
Default : G18(Lseries)/G17(Mseries)
Effectivetime : Instant
Note : SetthedefaultprocessingplanetoXYorXZ;modifythedefaultplane,so
thatit isn’t needto specifythe modalplane value whileprogramming,
andwriteplanerelatedinstructionsdirectlyinstead;
089
IPaddress
090
Subnetmask
091
Defaultgateway
Range : 0~255
Unit : None
Authority : Operationadminorhigher
Default :
192.168.0.123
255.255.255.0
192.168.0.1
Effectivetime : Restart
Note : Used to configure Ethernet parameters, which shall comply with the
actualnetworksettings,orelseitcan’tbeaccessednormally.
After configured successfully, the user can perform the
ping command