BZ001M056A ADT‐DK300A/400A Engraving Machine
101
094 EnableofG00Inpmode
Range : 0~1
Unit : None
Authority : Operationadminorhigher
Default : 0
Effectivetime : Instant
Note :
UsedtosetwhetherG00instructionismovedwithG01mode
IfG01mode isused,theinterpolationspeedshallfollowthe settingof
minimumspeed;
Theaccelerationisthe
interpolationacceleration.
095 Abnormalmemorylocationjumpenable
Range : ON~OFF
Unit : None
Authority : Operationadminorhigher
Default : ON
Effectivetime : Instant
Note : Used to restore the breakpoint position when the system is abnormal
during automatic processing. If the system has power failure or exits
abnormallyduringautomaticrunning,thesystemwillautomatically
save
current breakpoint location, and will prompt whether run from the
breakpoint after restarted. Press OK and the system will run from the
breakpoint,ignoringthecodesbeforethebreakpoint.
096 PauseZtosafeheightenable
Range : ON~OFF
Unit : None
Authority : Operationadminorhigher
Default : OFF
Effectivetime : Instant
Note : UsedtostopliftingZaxistosetsafeheightinautomaticprocessingfor
safety's sake. When processing is started, it first locates the position
beforetoollifting,andthen
carriesoutunfinishedprocessing.
097 PauseAtosafeheightenable
Range : ON~OFF
Unit : None
Authority : Operationadminorhigher
Default : OFF
Effectivetime : Instant
Note : UsedtostopliftingAaxistosetsafeheightinautomaticprocessingfor
safety's sake. When processing is started, it first locates the position
beforetoollifting,andthen
carriesoutunfinishedprocessing.