BZ001M056A ADTDK300A/400A Engraving Machine
108
in most cases (at 10mm/min processing speed), it can meet the
requirementonprocessingsafetycheck.
The hardware response function of hard limit is prior to scanning
response function, i.e. if the hardware response is enabled, it will
quicken the response speed directly. It should be noted that the
hardware response
function only can stop pulse in instant mode.
Therefore,theinstantstopmodemaycausemechanicalvibrationifthe
speed is too high. While software scanning mode uses maximum
acceleration mode and decelerates according to the maximum
accelerationsetto every axis bythe user(parameterP2.074~077),and
thereforeovershot
willoccur.

029
XPulseMode(rest art)
030
YPulseMode(restart)
031
ZPulseMode(restart)
032
4PulseMode(restart)
Range : 0~1
Unit : None
Authority : SuperAdmin
Default : 1
Effectivetime : Restart
Note : Pulsecommandformatsettingistoconfigurethemodeofoutputpulse.
Thecompatiblecommandformatofthemotordriveshouldbeknownin
advance.
Pulse+pulse
Pulse+direction

033
XPulseDirMode(restart)
034
YPulseDirMode(restart)
035
ZPulseDirMode(restart)
036
4PulseDirMode(restart)
Range : 0~1
Unit : None
Authority : SuperAdmin
Default : 1
Effectivetime : Restart