BZ001M056A ADTDK300A/400A Engraving Machine
122
infowhileprogramisrunning.
This parameter is dedicated for programmers, and the users are not
suggestedusingthisparameter.
Ifthetestinginfoisenabled,thesystemperforma ncewillbelowered,and
thereforeitisdisabledduringnormalprocessing.
If networking is enabled, this function must be disabled, or else
the
networkingwillfail.
020 axiscontrolcomposite
Range : 0~1
Unit : None
Authority : Superuser
Default : ON/1
Effectivetime : Instant
Note : Usedtoconfigurewhetherthekeyforaxismotiononthecontr olpanelis
enabled.
Thisparameterisusedtoshieldthecompositefunctionofthekeyforaxis
motionontheNCpanelandreduce thepossibilityofmisoperationwhen
additional panel is used. However, if no additional panel is used, this
parameter must be enabled, or else the axis motion can’t be controlled
throughthekey.
021 additionalpanelenable
Range : 0~1
Unit : None
Authority : Superuser
Default : OFF/0
Effectivetime : Instant
Note : Usedtoconfigure whetherNC usesadditionalpanel,whichmustbeADT
matching additional panel, or compatible with the interface of same
protocol.
If additional panel is used, the system testing info enable must be
deactivated(P3.19).
022 Mmacroprogramselection<>
Range : MFUNC(M),UserDef
Unit : None