BZ001M056A ADTDK300A/400A Engraving Machine
123
Authority : Superuser
Default : MFUNC(M)
Effectivetime : Instant
Note : Used to configure the auxiliary control of the system by calling
M_FUNC.NC or not. Through M_FUNC.NC fi le, the user can custom M
code function and panel control function. If this par amet er is set to
UserDef,
specificfunctionscanbeachievedthroughM_FUNC.NCprogram
fileunderD:\MACROdirectory.
023 Tmacroprogramselection<>
Range : TFUNC(M),UserDef
Unit : None
Authority : Superuser
Default : TFUNC(M)
Effectivetime : Instant
Note : Thisparametercanbeusedtodefinethetoolmagazineprogram.TFUNC
(M)isthebuiltintoolmagazineprogramofthesystem.Ifthisparameteris
set to UserDef, the
tool magazine function can be achieved by writing
M_FUNC.NCunderD:\MACROdirectory.
024 PLCprogramselection<>
Range : PLC(M),UserDef
Unit : None
Authority : Superuser
Default : PLC(M)
Effectivetime : Instant
Note : UsedtoconfiguretheauxiliarycontrolofthesystembycallingPLC(M).NC
ornot.
025 Screensaveron
Range : 0&1
Unit : None
Authority : Superuser
Default : 0
Effectivetime : Instant
Note : Usedtoconfigur ewhetherturnonscreensaverofthesystem,inorderto
furtherreducesystempowerconsumption.
Ifthe parameteris setto 1,the screendisplaywillautomaticallyturn off
afteroneminutewhenthesystemisstopped.