BZ001M056A ADTDK300A/400A Engraving Machine
134
Authority : Operationadminorhigher
Default : =========
Effectivetime : Instant
Note : Used for spindle speed control, corresponding to X3 input port of the
inverter
074 OilingOutPort
Range : 0~23
Unit : None
Authority : Operationadminorhigher
Default : OUT(05)=
Effectivetime : Instant
Note : Usedforoiloutputportconfiguration;thedefaultvalueis05
075 CoolerOutPort
Range : 0~23
Unit : None
Authority : Operationadminorhigher
Default : OUT(04)=
Effectivetime : Instant
Note : Usedforcooleroutputportconfiguration;thedefaultvalueis04
076 SpindleCWOutPort
Range : 0~23
Unit : None
Authority : Operationadminorhigher
Default : OUT(00)=
Effectivetime : Instant
Note : UsedforspindleCWoutputportconfiguration;thedefaultvalueis00
077 SpindleCCWOutPort
Range : 0~23
Unit : None
Authority : Operationadminorhigher
Default : OUT(01)
Effectivetime : Instant
Note : UsedforspindleCCWoutputportconfiguration;thedefaultvalueis01
078 SystemOilDectPort
Range : 0~23
Unit : None
Authority : Operationadminorhigher
Default : =========
Effectivetime : Instant
Note : Used for hydraulic pressure detection with auxiliary hydraulic control;
thedefaultvalueisnull
079 SpindleAlarmDetectPort