BZ001M056A ADTDK300A/400A Engraving Machine
135
Range : 0~23
Unit : None
Authority : Operationadminorhigher
Default : =========
Effectivetime : Instant
Note : Usedforinputdetectionportconfigurationofspindlealarmsignal;the
defaultvalueisnull;usedtogetherwithparameter069~072
080 TransduserDetectPort
Range : 0~23
Unit : None
Authority : Operationadminorhigher
Default : =========
Effectivetime : Instant
Note : Usedforinputdetectionportconfigurationofinverteralarmsignal;the
defaultvalueisnull.
081 ExScram2DetectPort
Range : 0~23
Unit : None
Authority : Operationadminorhigher
Default : =========
Effectivetime : Instant
Note : Usedforportconfigurationofexternalemergencystopinputsignal;the
defaultvalueisnull.
082 AirofToolCheckOutPort
Range : 0~23
Unit : None
Authority : Operationadminorhigher
Default : =========
Effectivetime : Instant
Note : Used for output port configuration of tool setter blowing; before tool
setting,blowthedebristoensurethetoolsettingaccuracy;thedefault
valueisnull.
083 IOConfinRESET00~15
Range : 0~65535
Unit : None
Authority : Operationadminorhigher
Default : =========
Effectivetime : Instant
Note : Usedtoconfigur etheoutputsignalthatshouldbereset.Forexample,to
resetoutput port of pin 10#whenthe systemis resetor alarms, press
EOBandset
OUT9inthepopupdialogbox(blackdotisselected),press
andholdEOBforthreesecondstoexit.