BZ001M056A ADT‐DK300A/400A Engraving Machine
136
084 IOConfinRESET16~23
Range : 0~65535
Unit : None
Authority : Operationadminorhigher
Default : =========
Effectivetime : Instant
Note : Theoutputsignalthatthesystemneedstoresetwhenconfiguringreset
andalarm;theconfigurationisOUT16~OUT23.
085 ExStart2DetectPort
Range : 0~23
Unit : None
Authority : Operationadminorhigher
Default : =========
Effectivetime : Instant
Note : Usedtoconfigureexternalstartbuttonwiringport;thedefaultvalueis
null
086 ExPause2DetectPort
Range : 0~23
Unit : None
Authority : Operationadminorhigher
Default : =========
Effectivetime : Instant
Note : Usedtoconfigureexternalstartbuttonwiringport;thedefaultvalueis
null
087 TCheckLimitDetectPort
Range : 0~23
Unit : None
Authority : Operationadminorhigher
Default : =========
Effectivetime : Instant
Note : Usedtoconfigureexternaltoolsetterlimitsignalport;thedefaultvalue
isnull
088 ServospindleenableoutputportNo.
Range : 0~23
Unit : None
Authority : Operationadminorhigher
Default : =========
Effectivetime : Instant
Note : Usedtoconfigureservospindleenablecontrolport;thedefaultvalueis
null.Afterthesystemspecifiesservospindlefunction,theservoenable
pincanbecontrolledthroughthisparameter
089 ServospindlequasistopoutputportNo.