BZ001M056A ADTDK300A/400A Engraving Machine
137
Range : 0~23
Unit : None
Authority : Operationadminorhigher
Default : =========
Effectivetime : Instant
Note : Usedtoconfigureservospindlestopdetectionport;thedefaultvalueis
null. In tool magazine, if spindle stop is required, start spindle stop
command, and determine whether stop in
place by detecting spindle
stopport
090 ServospindlepulsecontroloutputNo.
Range : 0~23
Unit : None
Authority : Operationadminorhigher
Default : =========
Effectivetime : Instant
Note : Usedto configurethe switchportofservospindle pulsecontrol mode;
thedefaultvalueisnull.Usedwhenservospindleisspecified.
091 ServospindlerigidtappingoutputNo.
Range : 0~23
Unit : None
Authority : Operationadminorhigher
Default : =========
Effectivetime : Instant
Note : Used to configure the servo spindle rigid tapping control output port;
thedefaultvalueisnull.Currentver sionisnotused.
092 ServospindlereadyinputNo.
Range : 0~23
Unit : None
Authority : Operationadminorhigher
Default : =========
Effectivetime : Instant
Note : Used to configure servo spindle ready input port; the default value is
null.
093 ServospindlequasistopinputportNo.
Range : 0~23
Unit : None
Authority : Operationadminorhigher
Default : =========
Effectivetime : Instant
Note : Usedtoconfiguretheservospindlestopinplaceinputport;thedefault
valueisnull.Currentversionisnotused.
094 ServospindlezerospeedinplaceinputportNo.